GASD 8000
Portable Gas Detector
Elevate Safety Standards with the GasD® 8000 Portable Gas Monitor
Product Information
In Pursuit of the Ultimate Portable Gas Detection System
Elevate Safety Standards with the GasD® 8000 Portable Gas Monitor
The GasD® 8000 Series portable analyzers redefine gas detection with cutting-edge advancements and superior functionality. These analyzers are equipped with a powerful sample pump and long-lasting rechargeable Lithium-Ion batteries, ensuring up to 8 hours of continuous operation. Designed for precision and ease of use, the GasD® 8000 Series features a digital readout, real-time graphics display, integral data logging, and both audible and visual alarms, providing comprehensive and accurate monitoring capabilities.
- Enhanced Safety: The GasD® 8000 Series ensures a high level of safety by providing real-time, accurate monitoring of toxic gases. Its audible and visual alarms alert users immediately to hazardous conditions, allowing for quick response and mitigation.
- Portability: With its compact and robust design, the GasD® 8000 Series is highly portable, making it ideal for use in various field applications. The rechargeable Lithium-Ion batteries support extended use, ensuring that the device is ready when needed.
- Ease of Integration: The analog outputs enable seamless integration with existing safety systems and data acquisition platforms, providing flexibility and compatibility with a wide range of industrial setups.
- Durability: Constructed with durable anodized aluminum, the GasD® 8000 Series is built to withstand harsh environmental conditions, ensuring long-term reliability and performance in demanding applications.
- User-Friendly Interface: The digital readout and real-time graphics display offer clear, easy-to-read information, while the integral data logging feature simplifies record-keeping and data analysis. These user-friendly features enhance operational efficiency and reduce the likelihood of errors.
- Trace (low level) gas sensing
- Capability to detect 21 gases
- Portable
- Extremely low level sensitivy (gas dependent)
- Active and continuous sampling with an integral sample pump, powered by rechargeable Lithium-Ion batteries
- Digital readout of concentration, along with real time graphics display
- Data logging
- Audible and visual alarm
- Analog output (4-20 mA and 0-2.5 V)
- 8 hours of continuous service
Accuracy | 5% |
Display | Sunlight visible transflective LCD |
Operating environment | 32°F – 113°F (0°C – 45°C); 0-90% relative humidity |
Internal Battery | Rechargeable Lithium-Ion (5000 mAh) |
Data Logging | Via integral SD card (32 GB) |
Dimensions | 5½ in H x 8¼ in W x 10 in D (140 x 210 x 254 mm) Includes body and legs |
Weight | 6.5 lb (2.95 kg) |
Enclosure | Anodized aluminum |
Power (when plugged in) | Universal AC outlet adapter. Rated voltage 100-240V, 50/60hz, USB A. Total output: 5V, 2400 mA or higher. |
Calibration | Against standard gas mixture, or via Interscan’s SENSOR EXPRESS® |
GASES WE DETECT
Why Interscan Detectors
0-Downtime Sensor Replacement
Replacement Sensors On-Demand, Right When You Need Them
Extremely Low-Level Gas Sensitivity
Real Time Data Logging
INDUSTRIES WE SERVE
COMMON QUESTIONS
For accurate readings, the pump must be on while measuring. When you enter Measure-mode, the default is “Mode: Off “ (this means the pump is off) With measure mode “off”, it may appear like the instrument is measuring, but it is not measuring actually. (If the pump is off the display will read Mode: Off as shown below)
To turn the pump on, from main menu with MEASURE highlighted, press the Right Arrow and press Enter The display should read “Mode:On” and now your device is actively measuring. This is process should be used each time a measurement is taken. If pump was previously “off”, then once the pump is turned-on, the user can confirm that the instrument is measuring gas.
If the pump was turned on and the sampling mode is set to “CON” (See FAQs), but measurements are still reading Zero, it may be necessary to reset the zero on the device to restore measurement accuracy. (is possible that the zero was inadvertently reset while the instrument was stabilizing and thus measurement below that “new zero” will always read zero)
To reset zero : The instrument should be in an environment without any analytes, then power the instrument. Measure will be highlighted. Press the right-arrow and then press Enter. The instrument display should say “Mode:On”.
Let the instrument stabilize for 30 minutes.
After 30 minutes , press the up-arrow button to Highlight Zero and press Enter. This will establish a new zero for the instrument sensor.
Press the Stop button.
Expose instrument to the target gas to confirm the new zero is established and non-zero readings are present. (If your instrument is still reading zero, then please contact our technical support department)

If the sampling mode is not set to “CON”, press the down-arrow to highlight Sampling Mode, then press the right-arrow. Then use the up and down arrow to scroll to highlight CON
Power off the instrument.
Power the instrument back on. Measure will be highlighted. Press the right-arrow and then press Enter The device should be begin measurement